HPLC-PDA “VERSUS” GC-MS IN THE ANALYSIS OF PARACETAMOL AND NON-STEROIDAL ANTI-INFLAMMATORY DRUGS IN WASTEWATER

Authors

  • Mihaela-Cătălina HERGHELEGIU Babeș-Bolyai University, Faculty of Environmental Science and Engineering, 30 Fântânele str., RO-400294, Cluj-Napoca, Romania. mihaela.herghelegiu@ubbcluj.ro
  • Aude ERNAULT École Supérieure de Physique et de Chimie Industrielle de la Ville de Paris, Paris Sciences et Lettres Université, 10 Vauquelin Rue, 75231, Paris, France
  • Mihail Simion BELDEAN-GALEA Babeș-Bolyai University, Faculty of Environmental Science and Engineering, 30 Fântânele str., RO-400294, Cluj-Napoca, Romania. simion.beldean@ubbcluj.ro https://orcid.org/0000-0002-6892-1223
  • Maria-Virginia COMAN Babeș-Bolyai University, “Raluca Ripan” Institute for Research in Chemistry, 30 Fântânele str., RO-400294, Cluj-Napoca, Romania. virginia.coman@ubbcluj.ro

DOI:

https://doi.org/10.24193/subbchem.2023.1.02

Keywords:

paracetamol and NSAIDs, solid-phase extraction, liquid-liquid extraction, GC-MS, HPLC-PDA

Abstract

The widespread use of paracetamol and non-steroidal anti-inflammatory drugs (NSAIDs) make them increasingly present in environmental factors, especially in water. The aim of this work was to develop an accurate, precise and sensitive analytical procedure for the simultaneous determination of Paracetamol and four NSAIDs (Ketoprofen, Naproxen, Diclofenac, and Ibuprofen). To this aim, the extraction (liquid-liquid extraction, LLE, and solid-phase extraction, SPE) as well as the chromatographic (high-performance liquid chromatography-photodiode array detector, HPLC-PDA, and gas chromatography-mass spectrometry in selected ion monitoring mode, GC-MS-SIM) techniques, in terms of the performances were compared. Different extraction solvents and types of cartridges at pH 3 of samples were tested for the extraction optimization. Low limits of detection and quantification at the g/L level were achieved. The developed HPLC-PDA and GC-MS-SIM methods were applied to the analysis of selected pharmaceuticals in different wastewater samples.

References

A. Azzouz; E. Ballesteros; Sci. Total Environ., 2012, 419, 208-215.

H. Montaseri; P. B. C. Forbes; TrAC., 2018, 108, 122-134.

T. Mackulak; S. Cernanský; M. Fehér; L. Birosová; M. Gál; Curr. Opin. Environ. Sci., 2019, 9, 40-48.

S. Esteban; Y. Valcárcel; M. Catalá; M. G. Castromil, Gac. Sanit., 2012, 26(5), 457-459.

T. Kosjek, E Heath, A Krbavcic, Environ. Int., 2005, 31, 679-685.

J Kumirska; A. Plenis; P. Łukaszewicz; M. Caban, N. Migowska; A. Białk-Bielinska, M. Czerwicka; P. Stepnowski; J. Chromatogr. A, 2013, 1296, 164-178.

C. H. Lee; Y. Shin; M. W. Nam; K. M. Jeong; J. Lee, Talanta, 2014, 129, 552-559.

P. Stepnowski; D. Wolecki; A. Puckowski; M. Paszkiewicz; M. Caban; Sci. Total Environ., 2020, 745, 140848.

M. Caban; K. Mioduszewska; P. Łukaszewicz; N. Migowska; P. Stepnowski;

M. Kwiatkowski; J. Kumirska; J. Chromatogr. A, 2014, 1346, 107-116.

J. Yan; W. Lin; Z. Gao; Y. Ren; Chemosphere, 2021, 279, 130529.

H. Montaseri; P. B. C. Forbes; TrAC., 2018, 108, 122-134.

K. Wieszczycka; J. Zembrzuska; J. Bornikowska; A. Wojciechowska; I. Wojciechowska; Chem. Eng. Res. Des., 2017, 117, 698-705.

J. C. G. Sousa; A. R. Ribeiro; M. O. Barbosa; M. F. R. Pereira; A. M. T. Silva, J. Hazard. Mater., 2018, 344, 146-162.

Y. Chen; Z. Guo; X. Wang; C. Qiu; J. Chromatogr. A, 2008, 1184, 191-219.

L. Nováková; H. Vlcková; Anal. Chim. Acta, 2009, 656, 8-35.

X. Chen; X. Wu; T. Luan; R. Jiang; G. Ouyang; J. Chromatogr. A, 2021, 1640, 461961.

N. Migowska; M. Caban; P. Stepnowski; J. Kumirska; Sci. Total Environ., 2012, 441, 77-88.

B. Huidobro-López; I. López-Heras; C. Alonso-Alonso; V. Martínez-Hernández; L. Nozal; I. de Bustamante; J. Chromatogr. A, 2022, 1671, 463006.

M. S. Beldean-Galea, R. Klein, M.-V. Coman; J. AOAC Int., 2020, 392-398.

T. Martinez-Sena; S. Armenta; M. de la Guardia; F. A. Esteve-Turrillas; J. Pharm. Biomed. Anal., 2016, 131, 48-53

J. L. P. Pavón; A. M. C. Ferreira; M. E. F. Laespada; B. M. Cordero; J. Chromatogr. A, 2009, 1216, 6728-6734

G. G. Noche; M. E. F. Laespada; J. L. P. Pavón; B. M. Cordero; S. M. Lorenzo; J. Chromatogr. A, 2011, 1218, 6240-6247.

B. Yilmaz; H. Sahin; A. F. Erdem; J. Sep. Sci., 2014, 37, 997-1003.

International Committee on Harmonization, “Validation of Analytical Procedures: Text and Methodology, Q2(R1), Nov. 2005. https://www.ema.europa.eu/en/documents/scientific-guideline/ich-q-2-r1-validation-analytical-procedures-text-methodology-step-5_en.pdf (Accessed December 2022).

Downloads

Published

2023-03-27

How to Cite

HERGHELEGIU, M.-C., ERNAULT, A., BELDEAN-GALEA, M. S., & COMAN, M.-V. (2023). HPLC-PDA “VERSUS” GC-MS IN THE ANALYSIS OF PARACETAMOL AND NON-STEROIDAL ANTI-INFLAMMATORY DRUGS IN WASTEWATER. Studia Universitatis Babeș-Bolyai Chemia, 68(1), 19–35. https://doi.org/10.24193/subbchem.2023.1.02

Issue

Section

Articles

Similar Articles