DETERMINATION OF COPPER IN ORANGE JUICE BY VOLTAMMETRIC TECHNIQUE: A COMPARATIVE STUDY OF SAMPLE PREPARATION METHODS
Keywords:
carbon paste electrode, 1,8-diaminonaphtalene, differential pulse anodic stripping voltammetry, rotating disk electrode, orange juiceAbstract
In the present work, carbon paste electrodes (CPE) modified with conducting polymers (1,8-diaminonaphthalene, 1,8-DAN) combined with rotating disk electrode (RDE) was applied to determine copper in orange juice samples. Copper (II) was preconcentrated at open circuit potential on the modified electrode. Then, the preconcentrated metals were oxidized by scanning the potential of the electrode from -0.4 to 0 V using differential pulse anodic stripping voltammetry (DPASV). Samples were analyzed with and without previous treatment. The current peak was high in orange juice sample digested with wet ashing and dry ashing procedures compared to those in sample without pretreatment. The wet ashing procedure was chosen for the digestion of orange samples because it required a shorter time. The results obtained were validated by inductively coupled plasma atomic emission spectroscopy (ICP-AES).
References
G. Barceloux, Clinical Toxicology, 1999, 37, 217.
*** - “Evaluation of certain food additives and contaminants (Twenty-sixth report of the Joint FAO/WHO Expert Committee on Food Additives)”, WHO Technical Report Series, No. 683, 1982.
H. Ofori, M. Owusu, G. Anyebuno, Journal of Scientific Research and Reports, 2013, 2, 423.
C.M.A. Iwegbue, S.O. Nwozo, E.K. Ossai, G.E. Nwajei, American Journal of Food Technology, 2008, 3, 220.
P.J.S. Barbeira, L.H. Mazo, N.R. Stradiotto, Analyst, 1995, 120, 1647.
C.A. Wijayawardhana, S. Purushothama, M.A. Cousino, H.B. Halsall, W.R.J. Heineman, Journal of Electroanalytical Chemistry, 1999, 468, 2.
M. Elyasi, M.A. Khalilzadeh, H. Karimi-Maleh, Food Chemistry, 2013, 141, 4311.
H. Karimi-Maleh, P. Biparva, M. Hatami, Biosensors and Bioelectronics, 2013, 48, 270.
M.R. Shahmiri, A. Bahari, H. Karimi-Maleh, R. Hosseinzadeh, N. Mirnia, Sensors and Actuators B, 2013, 177, 70.
R.M. Takeuchi, A.L. Santos, P.M. Padilha, Analytica Chimica Acta, 2007, 584, 295.
M.G. Enass, Talanta, 2010, 82, 646.
B.S. Sherigara, Y. Shivaraj, R.J. Mascarenhas, Electrochimica Acta, 2007, 52, 3137.
S. Majid, M. El Rhazi, A. Aziz, Microchimica Acta, 2003, 143, 195.
M. Coulibaly, M. El Rhazi, I. Adraoui, Journal of Analytical Chemistry, 2009, 64, 632.
K. Robards, M. Antolovich, Analyst, 1995, 120, 1.
J.K. Tufuor, J.K. Bentum, D.K. Essumang, J.E. Koranteng - Addo, Journal of Chemical and Pharmaceutical Research, 2011, 3, 397.
Z. Krejpcio, S. Sionkowski, J. Bartela, Polish Journal of Environmental Studies, 2005, 14, 877.
*** - “Guidelines for drinking water quality. Recommendations”, 1st Ed., WHO, Geneva, 1985, vol. 1, 130 p.