PRELIMINARY ASSESSMENT OF PARTICULATE CONCENTRATION NEAR COAL FIRED POWER PLANT

Authors

  • Bogdana VUJIĆ University of Novi Sad, Technical Faculty “Mihajlo Pupin” Zrenjanin, Serbia https://orcid.org/0000-0001-5249-8021
  • Vasile PODE University Politehnica Timisoara, Faculty of Industrial Chemistry, Timisoara, Romania
  • Jelena MIĆIĆ University of Novi Sad, Technical Faculty “Mihajlo Pupin” Zrenjanin, Serbia
  • Francisc POPESCU University Politehnica Timisoara, Faculty of Mechanical Engineering, Environmental Engineering, Timisoara, Romania. *Corresponding author: francisc.popescu@upt.ro https://orcid.org/0000-0001-7736-0758
  • Una MARČETA University of Novi Sad, Technical Faculty “Mihajlo Pupin” Zrenjanin, Serbia https://orcid.org/0000-0001-6664-0236
  • Adrian Eugen CIOABLA University Politehnica Timisoara, Faculty of Mechanical Engineering, Environmental Engineering, Timisoara, Romania https://orcid.org/0000-0001-6261-0064

DOI:

https://doi.org/10.24193/subbchem.2020.1.23

Keywords:

particulate matter, PM2.5, PM10, air quality assessment, large combustion plants

Abstract

This study shows the results of preliminary monitoring of particulate matter (PM10 and PM2.5) at four measurement points, during the three campaigns (spring, autumn, winter) The study was conducted for the first time in residential area near coal-fired power plant, Ugljevik, Bosnia and Herzegovina. The power plant flue gas cleaning equipment in the time of this research was out of the function. Authors investigated seasonal variations of PMs concentration levels, influence of terrain structure and meteorological condition on PMs distribution and identification of PMs origin sources. The results revealed that seasonal variation was more expressed in the case of PM2.5 concentration, while for PM10, occasionally episodic pollution (399µg/m³) was recorded. Also, it was noted that prevailing meteorological conditions and surrounding terrain structure could have limiting effect on PMs dispersion. In order to detect PMs origin, linear regression analysis was applied. Authors revealed that PM2.5 originating from power plant could be prescribed partly for M1 where the greatest correlation was calculated (R2=0,45). Although the measuring sites were set in proper position regarding dominant winds and terrain structure, it was identified that certain measurement sites were affected by the other local particulate matter sources, especially in case of PM10.

References

World Health Organization, Health Effects of Particulate Matter, 2013.

I.P.S. Araujo; D.B. Costa; R.J.B. De Moraes; Sustainability, 2014, 6, 7666-7688.

S.A. Mohd Din; N.N.H. Nik Yahya; A. Abdullah; Procedia – Social Behavioral Sci., 2013. 85, 92 – 99.

Z. Wang; C. Zhang; G. Lv; X. Sun; N. Wang; Z. Li; Int. J. Mol. Sci. 2019, 20, 3746.

B. Jiang; D.Xia; X. Zhang; Sci Total Environ. 2018, 616-617, 1414-1422.

S. Hu Lee; H. Gordon; H. Yu; K. Lehtipalo; R. Haley; Y. Li; R. Zhang; J Geograph. Res.: Atmosph., 2019, 124, 7098-7146.

S. Mohankumara, P. Senthilkumarb; Renew. Sus. Energ. Rev., 2017, 80, 1227–1238.

I.A. Chereches; I. Petean; G.A. Paltinean; A. Mocanu; L. Muresan; G.Arghir; M. Tomoaia-Cotisel; Studia UBB Chemia, 2018, 63, 159-166.

Z. Ma; Z. Li; J. Jiang; J. Deng; Z. Yu; S. Wang; L. Duan; Aerosol Air Qual. Res., 2017, 17, 636–643.

EIA, Institute for construction, Banja Luka, 2016.

B. Stojanović; S.Đukić; Međunarodna konferencija "Elektrane 2014", Zlatibor, 2014.

M. Holland; Technical report on goal fired power plants impact on health in West Balcan, Health and Environmental Alliance, Brussels, Belgium; 2016, pp 16-23 (in Serbian).

Directive 2008/50/EC, Official Journal of the European Union, 2008.

FHMS Jugoslavije, Meteorološki godišnjaci I, 1961-1985.

RHMS RS, FHMI FBiH. Dokumentacija 1986-1990.

G. Xu; L. Jiao; B. Yhang; S. Yhao; M. Yuan; Y. Gu; J. Liu; X. Tang; Aerosol Air Qual. Res., 2017, 17, 741–751

N. Sugimoto; A. Shimizu; I. Matsui; M. Nishikawa; Particuology, 2016, 28, 114–120.

B. Vujić; A. Pavlović; G. Vujić; D. Jevtić; Rev.Chim., 2010, 61, 991-997.

V. Valverde; M.T. Pay; J.M. Baldasano; Sci. Total Environ., 2016, 541, 701–713.

BHAS 2013 - Agency for Statistics of Bosnia and Herzegovina, 2013.

Z. Milovanović; V. Sijacki- Zeravcic; D. Milanovic; S. Borojevic; In book: Prijedlog mjera i aktivnosti na uvođenju optimalnog upravljanja pokazateljima konkurentnosti energetskih I procesnih postrojenja (uvođenje ASSET MANAGEMENT-a na najvišem nivou) - faza I, Edition: I, Chapter: IV Modul I, 2009, Publisher: Univerzitet u Banjoj Luci, Mašinski fakultet, Banja Luka, Bosnia and Herzegovina.

Downloads

Published

2020-03-20

How to Cite

VUJIĆ, B., PODE, V., MIĆIĆ, J., POPESCU, F., MARČETA, U., & CIOABLA, A. E. (2020). PRELIMINARY ASSESSMENT OF PARTICULATE CONCENTRATION NEAR COAL FIRED POWER PLANT. Studia Universitatis Babeș-Bolyai Chemia, 65(1), 291–303. https://doi.org/10.24193/subbchem.2020.1.23

Issue

Section

Articles

Most read articles by the same author(s)

Similar Articles

<< < 9 10 11 12 13 14 15 16 17 18 > >> 

You may also start an advanced similarity search for this article.