KINETICS OF THE CORROSION PROCESS OF HOT DIP GALVANIZED STEEL REINFOCEMENT IN FRESH CONCRETE

Authors

  • Vasile RUS S.C. Betak S.A., Bistrita, Romania. Email: rusvasile@betak.ro.
  • Andreea-Cristina HEGYI INCD URBAN-INCERC, Centre, Technical University; National Institute for Research and Development in Construction and Economy of Construction, Cluj-Napoca, Romania. Corresponding author: rusvasile@betak.ro. https://orcid.org/0000-0001-8453-527X
  • Horațiu VERMEŞAN Faculty of Materials and Environmental Engineering, Technical University of Cluj-Napoca, Cluj-Napoca, Romania. Email: horatiu.vermesan@imadd.utcluj. https://orcid.org/0000-0001-9554-2715
  • Ancuța Elena TIUC Faculty of Materials and Environmental Engineering, Technical University of Cluj-Napoca, Cluj-Napoca, Romania. Email: ancuta.tiuc@imadd.utcluj.ro. https://orcid.org/0000-0001-6227-1824

Keywords:

hot dip galvanized steel reinforcement, concrete, corrosion, calcium hydroxizincate

Abstract

The quality of concrete structures is largely reflected by its durability. According to literature, the rebar corrosion initiation is delayed and the life duration of concrete structures reinforced with hot dip galvanized rebar is extended with up to 70 years compared to life duration of concrete structures reinforced with non-galvanized steel rebar. It is well known that the galvanized rebar surface activates in contact with the alkaline environment of fresh concrete, forming a crystalline compound namely calcium hydroxizincate. This crystalline compound is important for the kinetic and corrosion mechanism of rebar embedded in concrete. This work aims to evidence the galvanized rebar corrosion kinetics in fresh concrete, during the concrete hardening. Electrochemical methods were used during experiments. The test results show an activation of the zinc layer of galvanized rebar in contact with the alkaline environment of concrete, during the first days after rebar embedding in concrete. Zinc corrosion products formation lead to better corrosion resistance of galvanized steel rebar, compared to the resistance of non-galvanized steel rebar.

References

M.C. Alonso, I. Martinez, J. Fullea, V. Ibarra, In-situ monitoring of galvanised reinforced concrete structures. The Spanish experience, INTERGALVA, Madrid 2009.

C. Andrade, C. Alonso, Constr Build Mater, 1996, 10(5), 315.

C. Andrade, C. Alonzo, Electrochemical Aspects of Galvanized Steel, in Galvanized Steel Reinforcement in Concrete, Elsevier, Editor S.R. Yeomans, 2004, 111.

T. Belleze, M. Malavolta, A. Quaranta, N. Ruffini, G Roventi, Corrosion behavior in concrete of three differently galvanized steel bars, Cement & Concrete Composites, 2006, 28.

M. Carbucicchio, R. Ciprian, F. Ospitali, G. Palombarini, Corrosion Science, 2008, 50 (9), 2605.

I. Cornet, B. Bresler, Galvanized reinforcement for concrete – II, International Lead Zinc Research Organization, New York, 1981, 1.

J.A.A. Gonzàlez, British Corrosion Journal, 1982, 17(1), 21.

I. Lingvay, Coroziunea provocata de curenții de dispersie vagabonzi, Ed. Electra, București, 2005, 25, 113.

C. Mircea, Durabilitatea elementelor și structurilor de beton precomprimat, http://www.incerccluj.ro, iunie 2005, 7.

V. Nicolau, Betonul armat, Ed. Tehnică, București, 1962, 7, 25, 93, 108, 163.

I. Nicula, T. Oneț, Beton armat, Ed. Didactica și Pedagogică, București, 1982, 5, 40.

T. Visan, Electrochimie si coroziune pentru doctoranzii ELCOR, Ed. PRINTECH, Bucuresti, 2002.

S.R. Yeomans, Galvanized Steel in Reinforced Concrete, Elsevier B.V., Amsterdam, 2004, 297.

S.R. Yeomans, Considerations of the characteristics and use of coated steel reinforced in concrete, NISTIR 5211, Univ. New South Wales, Canbera, 2004.

C. Budan, D.N. Stoica, A.M. Cotescu, Revista Romana de Materiale, 2010, 40(2), 132-140.

S.R. Yeomans, Corrosion, 1994, 50, 72.

Andreea Hegyi, H. Vermeșan, G. Vermeșan, V. Rus, Internaționale Conference on Advanced Composites Engineering COMAT Brasov 2010, 116.

Andreea Hegyi, H. Vermeșan, G. Vermeșan, V. Rus, E. Grunwald, Research on the corrosion protection of galvanized rebar in concrete, Jahrbuch Oberflachen technic, band 66, Eugen G. Leuze Verlag, Germania, 2010, 229.

Andreea Hegyi, H. Vermeșan, V. Rus, International Review of Applied Science & Engineering, 2010, 1(1-2), 45.

Andreea Hegyi, V. Rus, C. Bumbuc, H. Vermeșan, Metalurgia International, 2011, 16, 6, 10.

Andreea Hegyi, H. Vermeșan, C. Bumbuc, Metalurgia International, 2010, 15, 11, 74.

Downloads

Published

2015-06-30

How to Cite

RUS, V. ., HEGYI, A.-C. ., VERMEŞAN, H. ., & TIUC, A. E. . (2015). KINETICS OF THE CORROSION PROCESS OF HOT DIP GALVANIZED STEEL REINFOCEMENT IN FRESH CONCRETE. Studia Universitatis Babeș-Bolyai Chemia, 60(2), 409–419. Retrieved from https://studia.reviste.ubbcluj.ro/index.php/chemia/article/view/8461