QUALITATIVE EVALUATION OF 3D PRINTED BONE MODEL STRUCTURES WITH COMPUTED TOMOGRAPHY

Authors

DOI:

https://doi.org/10.24193/subbphys.2025.05

Keywords:

3D printing, bird bones, CT evaluation, bone replica

Abstract

3D printing enables accurate physical models for surgical planning, education, and research, while computed tomography (CT) remains a primary modality for visualizing internal structures. This study evaluated the fidelity of 3D-printed replicas of a chicken bone. High-resolution CT scans were processed with 3D Slicer and UltiMaker Cura, and six replicas were produced with four printers spanning Fused Deposition Modeling (FDM) and Stereolithography (SLA). Replicas and the original bone were scanned together across eight studies with varied parameters, reconstructed with BONE and STD kernels, and compared through Hounsfield Unit (HU) analysis. A biocompatible ABS closely matched real bone in HU, indicating high radiodensity fidelity, whereas a hollow resin replica approached air-equivalent values. The results confirm 3D printing’s potential for medical training and anatomical models and highlight the importance of careful material and parameter selection.

Author Biographies

  • Filip Orzan, Babeș-Bolyai University

    Filip Orzan, researcher and PhD student, Faculty of Physics, Babeș-Bolyai University, Cluj-Napoca, Romania

  • Maria Tudose, Babeș-Bolyai University

    Maria Tudose, MA student, Department of Biomedical Physics, Faculty of Physics, Babeș-Bolyai University, Cluj-Napoca, Romania

  • Flavia Coste, Babeș-Bolyai University

    Flavia Coste, MA student, Department of Biomedical Physics, Faculty of Physics, Babeș-Bolyai University, Cluj-Napoca, Romania

  • László Szabó, Babeș-Bolyai University

    Researcher László Szabó, PhD, Department of Biomedical Physics, Faculty of Physics, Babeș-Bolyai University, Cluj-Napoca, Romania

  • Zoltán Bálint, Babeș-Bolyai University

    Professor Zoltán Bálint, PhD, Department of Biomedical Physics, Faculty of Physics, Babeș-Bolyai University, Cluj-Napoca, Romania.
    * Corresponding author: zoltan.balint@ubbcluj.ro

References

1. G. D. Rubin, “Computed Tomography: Revolutionizing the Practice of Medicine for 40 Years”, Radiology, 273, S45–S74 (2014).

2. P. J. Withers et al., “X-ray computed tomography”, Nat. Rev. Methods Primers, 1, 1–21 (2021).

3. J. Meyer-Szary et al., “The Role of 3D Printing in Planning Complex Medical Procedures and Training of Medical Professionals — Cross-Sectional Multispecialty Review”, Int. J. Environ. Res. Public Health, 19, 3331 (2022).

4. D. Salazar, M. Thompson, A. Rosen, and J. Zuniga, “Using 3D Printing to Improve Student Education of Complex Anatomy: a Systematic Review and Meta-analysis”, Med. Sci. Educ., 32, 1209–1218 (2022).

5. X. Ou et al., “Recent Development in X-Ray Imaging Technology: Future and Challenges”, Research, 2021, 9892152 (2021).

6. “Hounsfield unit”, Radiopaedia.org. [Online]. Available: https://radiopaedia.org/articles/hounsfield-unit [Accessed Mar. 21, 2025].

7. H. K. Huang, “PACS, Image Management, and Imaging Informatics”, in Multimedia Information Retrieval and Management, D. D. Feng, W.-C. Siu, H.-J. Zhang, Eds., Springer, Berlin, 2003, pp. 346–365.

8. K. Agashe, A. Sachdeva, and S. Chavan, “3D printing and advanced material technology”, Int. J. Grid Distrib. Comput., 13, 1899–1936 (2020).

9. R. Mendenhall and B. Eslami, “Experimental Investigation on Effect of Temperature on FDM 3D Printing Polymers: ABS, PETG, and PLA”, Appl. Sci., 13, 11503 (2023).

10. Santesoft, Sante DICOM Viewer Lite. [Online]. Available: https://santesoft.com/win/sante-dicom-viewerlite/sante-dicom-viewer-lite.html [Accessed Apr. 28, 2025].

11. M. Arnould et al., “The untapped potential of 3D virtualization using high resolution scanner-based and photogrammetry technologies for bone bank digital modeling”, Comput. Biol. Med., 179, 108813 (2024).

12. K. Mei, P. Pasyar, M. Geagan, L. P. Liu, N. Shapira, G. J. Gang, J. W. Stayman, and P. B. Noël, “Design and fabrication of 3D-printed patient-specific soft tissue and bone phantoms for CT imaging”, Sci. Rep., 13, 17495 (2023).

13. X. Ma, M. Figl, E. Unger, M. Buschmann, and P. Homolka, “X-ray attenuation of bone, soft and adipose tissue in CT from 70 to 140 kV and comparison with 3D printable additive manufacturing materials”, Sci. Rep., 12, 14580 (2022).

Downloads

Published

2026-10-08

Issue

Section

Articles

How to Cite

Orzan, F., Tudose, M., Coste, F., Szabó, L., & Bálint, Z. (2026). QUALITATIVE EVALUATION OF 3D PRINTED BONE MODEL STRUCTURES WITH COMPUTED TOMOGRAPHY. Studia Universitatis Babeș-Bolyai Physica, 70(1-2), 49-67. https://doi.org/10.24193/subbphys.2025.05

Most read articles by the same author(s)